CHANGEN, founded in Guangzhou in 2012, develops the fibre-optic transceivers, shielded cameras, antenna stands, low-dielectric fixtures and probes that carry signals out of the chamber and hold the test setup exactly as the standard describes. ICX Lab is the authorised distributor.

Why fibre

Watch the product under test without disturbing the field

Every copper cable that leaves the chamber changes the test. CHANGEN transceivers convert bus and analogue signals to light at the equipment under test, so the operator sees the same data outside the chamber with nothing conductive crossing the wall.

Every vehicle busLIN, CAN FD, 100M to 10G automotive Ethernet, A2B audio and industrial Ethernet, each with a matching transceiver pair.
Immune to the fieldTransceivers are built to keep working at radiated immunity levels, with the current transceiver rated for 300 V/m continuous wave.
Standards firstFixtures and probes follow the standard drawing: CISPR 15, ISO 11452, CISPR 25 and OEM specifications such as Toyota TSC050.
Engineered, patented33 Chinese and 5 US invention patents, ISO 9001 certified, and a member of the IEEE, OPEN Alliance and EtherCAT standards communities.

Signal path during an immunity test

INSIDE THE CHAMBER Equipmentunder test LIN, CAN FD, Ethernet, analogue copper CHANGEN optictransceiver electrical to light shield wall fibre waveguide fibre Receiver in thecontrol room light back to electrical EMC test software bus analyser, video, data logger e.g. Nexio BAT-EMC monitoring CONTROL ROOM
Optic transceivers

One transceiver pair for each bus on the product

Each model converts a specific bus or signal to fibre at the equipment under test and back to electrical at the control room.

CHANGEN OPT-LIN22-B1 LIN optic transceiver

OPT-LIN22-B1

LIN bus optic transceiver, latest generation.

Details →

CHANGEN OPT-CANFD-B1 CAN FD optic transceiver

OPT-CANFD-B1

CAN FD bus optic transceiver up to 12 Mbps.

Details →

CHANGEN OPT-ETHER-B1 vehicle Ethernet optic transceiver

OPT-ETHER-B1

100 Mbps and 1 Gbps vehicle Ethernet optic transceiver.

Details →

CHANGEN OPT-ETHXG-A1 multi-gigabit vehicle Ethernet optic transceiver

OPT-ETHXG-A1

2.5G, 5G and 10G automotive Ethernet optic transceiver.

Details →

CHANGEN OPT-ETNXG-A1 industrial Ethernet optic transceiver

OPT-ETNXG-A1

2.5G, 5G and 10G industrial and IT Ethernet optic transceiver.

Details →

CHANGEN OPT-AN20K analogue optic transceiver

OPT-AN20K-B2 / B8

Two or eight channel analogue optic transceiver for signals to 20 kHz.

Details →

CHANGEN OPT-DC100-B1 current optic transceiver

OPT-DC100-B1

Current optic transceiver, rated to keep working at 300 V/m continuous wave.

Details →

CHANGEN OPT-A2B28-A1 A2B optic transceiver

OPT-A2B28-A1

A2B automotive audio bus optic transceiver, up to 10 nodes.

Details →

RF over fibre

Replace long coaxial runs with fibre

RF fibre-optic links carry antenna and probe signals across the chamber without the loss, pickup and ground loops of coax.

CHANGEN single-channel RF fibre-optic system

Single-channel RF fibre-optic system

9 kHz to 40 GHz in one channel, customisable to 100 GHz. Also available in 9 kHz to 1 GHz, 100 kHz to 1 GHz, 1 GHz to 6 GHz and 1 GHz to 40 GHz versions.

Details →

CHANGEN eight-channel RF fibre-optic system

Eight-channel RF fibre-optic system

100 kHz to 6 GHz across eight channels for multi-antenna and multi-probe setups.

Details →

Shielded cameras and projectors

See displays and indicators from outside

Cameras and projectors built to work inside the field, so BAT-IMAGE and similar video monitoring can watch dashboards, screens and warning lights during the test.

CHANGEN HD316 shielded camera

HD316

EMC full-HD 1080p shielded camera.

Details →

CHANGEN HDB207 shielded projector

HDB207

Full-HD shielded projector for dark chambers.

Details →

CHANGEN HDB230 shielded projector

HDB230

Full-HD shielded projector, higher output.

Details →

CHANGEN LM118P light intensity monitor

LM118P

Fifth-generation light-intensity monitoring probe.

Details →

CHANGEN VTS150 visual target simulator

VTS150

Visual target simulator system for camera-based driver-assistance products.

Details (Chinese) →

CHANGEN fibre wall-penetration waveguide

Fibre waveguide

Shielded wall-penetration waveguide for optical fibre.

Details (Chinese) →

Antenna stands and positioners

Hold the antenna where the standard says

CHANGEN 9120J antenna stand

9120J

Antenna stand compatible with horn antennas from several brands.

Details (Chinese) →

CHANGEN 9120K pneumatic antenna stand

9120K

Pneumatic lifting antenna stand with air-powered height adjustment.

Details (Chinese) →

CHANGEN TPM150 universal stand

TPM150

Universal telescopic tripod stand.

Details (Chinese) →

CHANGEN MPF900 whip antenna cart

MPF900

Mobile support cart for single whip antennas.

Details (Chinese) →

CHANGEN 3126 large horn antenna stand

3126

Large horn antenna stand built for ETS-Lindgren horns.

Details (Chinese) →

CHANGEN biconical antenna stand

Biconical antenna stand

For VHBB 9124 and BBA 9106 antennas, with polarisation adjustment.

Details (Chinese) →

CHANGEN portable antenna stand

Portable antenna stand

Folding stand for field and on-site tests.

Details (Chinese) →

CHANGEN customised antenna bracket

Customised brackets

Antenna brackets made to your antenna and chamber.

Details (Chinese) →

2 m turntableCompact turntable for component and small-EUT chambers.
4 m antenna towerAntenna mast for 1 m to 4 m height scan in 3 m chambers.
Steering-wheel rotation systemBionic actuator that turns the steering wheel during vehicle immunity tests.
Low-dielectric fixtures

Support the product without reflecting the field

Patented low-dielectric-constant material for test tables and fixtures where a normal table would distort the measurement.

CHANGEN low-dielectric support material

Low-dielectric support material

Support blocks for automotive EMC setups that need a low-dielectric material.

Details (Chinese) →

CHANGEN low-dielectric test table

Low-dielectric test table

Low-reflection test table for laboratories that lack one.

Details (Chinese) →

CHANGEN CDNE100 luminaire fixture

CDNE100

Pre-drilled support fixture for luminaire testing.

Details (Chinese) →

CHANGEN Mb0505 square loop antenna

Mb0505

Square loop antenna on patented low-dielectric support.

Details (Chinese) →

CHANGEN FPC2000 electrostatic field coupling plate

FPC2000

Electrostatic field coupling plate.

Details (Chinese) →

CHANGEN charging pile winding board

Charging-pile winding board

Cable winding board for EV charger EMC tests.

Details (Chinese) →

Passive antennas and probes

Built to the drawing in the standard

CHANGEN VP0505N voltage probe

VP0505N

Voltage probe to the Toyota engineering standard TSC050.

Details (Chinese) →

CHANGEN BSA broadband sleeve antenna

BSA18650 / BSA10835

Broadband sleeve antennas built to the ISO method.

Details (Chinese) →

CHANGEN MLWA500 long wire antenna

MLWA500

Long wire antenna.

Details (Chinese) →

CHANGEN TPL3000 tri-plate antenna

TPL3000

Tri-plate antenna, an open TEM cell without side walls.

Details (Chinese) →

Systems and consumables

Dynamometers, switching and the small things

Dynamometers and systems

Consumables and placement aids

Why through ICX Lab

Accessories chosen for your chamber and your software

Fits the chamberWaveguides, fixtures and stands specified together with a Frankonia chamber project or fitted to the room you already have.
Fits the softwareTransceivers and cameras feed Nexio BAT-EMC EASY-MONITORING, CAN bus and BAT-IMAGE monitoring during immunity tests.
Right model first timeWe match the transceiver to the bus, speed and node count on your product before you order.
Delivery and supportQuotation, import and after-sales handled from Penang.

Product names, model numbers and images are those of Guangzhou Changen Electronic Technology Co., Ltd. (CHANGEN®), taken from chan-gen.com. Links marked "Chinese" open product pages that are published in Chinese only. Specifications are subject to change; refer to the manufacturer's datasheets.

Tell us what you need to test

We reply within one working day with a quote or a plan.

Contact us